As the need for connectivity continues to grow extensively, more telecommunications equipment such as cellular base stations and satellite communication devices are installed in urban as well as remote locations. Small wind turbines can be cost-effectively used to power such telecommunication sites.

Wind power secures constant power supply, which is crucial for telecom services and reduces the need for ongoing maintenance such as fuel and equipment transportation. Reliable energy supply and significant cost savings, increase wind power competitiveness and turn it into the best energy choice for telecom and network operators.

ComSpin C wind power solutions are designed to power a wide range of telecom sites at grid-connected and off-grid locations worldwide. Installed on a telecom tower, the ComSpin C is best suited as a stand-alone power source as well as a hybrid solution with additional power sources, such as diesel generators or photovoltaic cells. ComSpin C is an ideal powering solution for:

  • TV and radio stations
  • Cellular base stations
  • Landline telephone exchange hubs
  • Wireless internet sites
  • Monitoring stations
  • and many more…
telecom_3m

ComSpin S wind power solutions - for satellite communication devices

Features

  • Reliable and maintenance-free operation at wider range of wind speeds
  • Unmatched efficiency of up to 45% guaranteeing more power generation
  • Unsurpassed silent and vibration-free operation ensuring interference free environment for the telecom equipment
  • Light weight and lower load enabling installation on telecom towers

Benefits

  • Lowest cost of ownership
  1. Quick and cost saving installation enabled by utilizing the existing telecom towers made possible due to low loads  and vibration-free operation
  2. More power generation in wider wind ranges
  3. Maintenance free, renewable energy, best serving stand-alone telecom applications (saving fuel transportation and logistics operations expenses)
  • Top efficiency and reliability
  1. Robust and reliable operation yielding continuous, uninterrupted power generation
  2. Power generation in low winds (2.5m/s) as well as survival wind of 200km/h (55m/s)
  • Silent and vibration free operation under all wind conditions, ensuring uninterrupted operation of telecom equipment

Configuration Options overview

  • Stand Alone (Off Grid)
  1. Connection is suitable in sites off grid sites
  2. Options of connection to battery bank using charge controller OR connection to diesel generator using an inverter
  3. Options for wind turbine only or hybrid wind and PV - Hybrid system benefits from complimentary energy cycles from each technology (day/night, summer/winter, etc.)
  • Grid Connected
  1. Connection is suitable in grid connected sites
  2. Options of connection to grid only (stable grid sites) OR connection to grid with diesel generator as secondary system (unstable grid sites)

Stand Alone (Off-Grid) Configuration Options

  • Connection of wind turbine/s to the battery bank with charge controller
telecom_battery_config
  1. Connection is suitable in sites that include large battery bank and diesel generator charges batteries every few hours (non continuous DG operation)
  2. The power generated by the turbine/s charges the batteries and reduces diesel generator costs
  • Connection of hybrid wind turbine/s and PV to the battery bank using charge controllers
telecom_hybrid_batteries
  • Connection of wind turbine/s directly to Diesel Generator using an inverter
telecom_standalone_dg
  1. Connection is suitable in sites that include a diesel generator working on continuous basis and small back up battery bank
  2. The power generated by the turbine/s reduces required DG output level and thus reduces DG costs
  • Connection of hybrid wind turbine/s and PV directly to Diesel Generator using inverters
telecom_hybrid_dg

Grid Configuration Options

  • Connection of wind turbine/s to the grid using the inverter
telecom_grid_stable
  1. Connection is suitable in sites that are connected to a stable grid
  2. The power generated by the turbine/s is supplied to the grid, thus reducing the costs for purchasing the power for the site (only the balance is used from the grid).
  • Connection of wind turbine to grid and diesel generator (as secondary system) using inverter
telecom_grid_unstable
  1. Connection is suitable in sites that are connected to an unstable grid
  2. The power generated by the turbine/s is supplied to the grid, and in case of grid failure, the turbine/s power is diverted to the diesel generator. Savings in grid and DG costs.

Inverters for connection to grid / diesel generator

ComSpin C series turbines are compatible with the following inverters that connect the wind turbines either to the grid system or to directly to the diesel generator:

Ginlong gci-2k-2a

Inverter| GCI-2K
Max output | 2.2KW
Certifications | UL 1741, AS 4777, G83/1 and other related international standards
Configuration | Each turbine model requires a different number of inverters connected in parallel

Turbine number of inverters per turbine
ComSpin C 2200 1
ComSpin C 4000 2
ComSpin C 8000 5
ComSpin C 13000 9

Link to manufacturer's site

Aurora

wind_inverters

Inverter| PVI-3600-OUTD, PVI-6000-OUTD
Max output | 3.6KW and 6KW
Certifications | UL1741 and international standards
Configuration | Some turbine models require a few inverters connected in parallel, three ComSpin C 2200 turbines can be connected to one PVI-6000 inverter

Turbine Inverter Number of Inverters per turbine
ComSpin C 4000 PVI 3600 1
ComSpin C 8000 PVI 6000 2
ComSpin C 13000 PVI 6000 3

Link to manufacturer's site

 

 

ComSpin C Products

(click product name to view specs)

ComSpin C Series Overview
3.5-8m rotor and 2.2-13Kw rated capacity

ComSpin C 2200
3.5m rotor and 2.2Kw rated capacity

ComSpin C 4000
4.2m rotor and 4 kW rated capacity

ComSpin C 8000
6m rotor and 8Kw rated capacity

ComSpin C 13000
8m rotor and 13Kw rated capacity

 

Overview of solution for Telecom integrators

4kw_mini

 

 

 

Click here for document

TechoSpin References

 

Click here for refrences page

You can download the company